What is Network Observatory

What it is

Network Observatory is the real-time monitoring module of CreaRack Pro. It watches every device in your infrastructure that has an IP address — switches, routers, servers, access points, UPS units, signage players — and tells you what is up, what is slow and what is failing before your users notice.

Each monitored device can run independent checks. Enable any combination:

  • Ping (ICMP) — availability, latency and packet loss. The baseline check.
  • SNMP — bandwidth per interface (v2c or v3), interface errors and discards, plus CPU, memory and temperature on devices with known vendor OIDs.
  • HTTP — health checks for web services (status code, response time and SSL certificate validity). The device tab has no HTTP section today, so it cannot be set up from there; to watch a web service, use a TCP Probe on its port. See [[crearack—monitoring—ping-http]].

On top of the raw checks, Observatory adds configurable alerts, an AI analysis layer (CNS), an ITSM tab for incident management, and a Network Tutor chat for networking questions.

Two monitoring modes

The Sentinel Mode panel in the sidebar controls who runs the checks:

ModeWho pollsWhen
Cloud OnlyThe platform, triggered by your open browser tabOnly while Observatory is open
SentinelThe Local Agent on your network24/7, even with the browser closed

With a Primary agent and no mode ever saved, the panel shows 24/7 Sentinel; with no Agent at all it warns Private networks are not being monitored and offers Download Agent. Click Change in the panel to switch. In Sentinel mode the Agent runs the checks 24/7 and pushes the results to the cloud. In both modes, how often each device is checked is up to you: every device has its own Polling cadence (15 s to 5 min, default 1 min), set in its card editor — see [[crearack—network—device-page]]. Agent status and management live in the Agent Fleet widget — see [[crearack—monitoring—fleet-manager]].

The interface

  • Sidebar (left) — your device list with a Devices / Manual source toggle, free-text search (by name, address or serial number) and filters by type, status, group and rack. Every row has a checkbox, with Select all, “N selected” and Clear above the list, and three buttons at the bottom — Refresh All, Deep Data and Manage Groups — that act on the ticked rows or, if none is ticked, on what the list shows (never on the whole fleet while it is filtered). Hover a button to read what it will act on. Below the list: the Sentinel Mode panel, Chart Defaults, alert severity cards (Good / Info / Critical) and the Network Tutor button. Drag the edge to resize (280-560 px).
  • Workspace (right) — fixed tabs Overview (fleet dashboard), CNS (AI insights) and ITSM (incidents), plus one tab per device you open. Open tabs are saved and restored on reload.

Deep Data, at the bottom of the sidebar, probes the SNMP devices in that scope for vendor details and extra metrics — see [[crearack—monitoring—deep-discovery]]. It is greyed out in the Manual view, because manual targets do not support it. The Targets Down figure of the Overview is a button too: click it to show only the devices that are down in the list.

How to start monitoring a device

  1. Devices managed in CreaRack (racks, Auto-Provision) appear under Devices automatically. For anything else, click Add and enter a name and IP — this creates a manual target with ping only; turn SNMP on from Settings in the Bandwidth (SNMP) section.
  2. Click the device in the sidebar. A tab opens. If it is not monitored yet, click Enable Monitoring.
  3. Ping starts immediately. For bandwidth, configure SNMP credentials — see [[crearack—monitoring—configurar-snmp]]. The device tab has no HTTP section, so web checks cannot be set up from there today.
  4. Optionally define thresholds via the Alerts buttons — see [[crearack—monitoring—alertas]].

Within minutes the charts fill with data and you can browse history — see [[crearack—monitoring—dashboards]] and [[crearack—monitoring—metricas]].

Taking a device out of service

Some equipment is only used part of the time — reinforcement access points that go out for an event and come back to the storeroom, a spare UPS, a screen that is packed away between shows. A device that is switched off on purpose is not a fault, and it should not look like one.

Open the device and click Take out of Service, then confirm. Since version 1.188.0 you can also do it from the device list on the left: every row carries a small button next to the × that deletes the device, which also replaces the old coloured status dot: green In service (monitored and answering), red Not connected (monitored but not answering) or orange Out of service. Click it, confirm, and the device changes state without opening its card. A device with no monitoring target has no button and keeps its status dot. The list is sorted by name. From that moment the device:

  • stays in the list, greyed out — it does not disappear, and it keeps its card and all its history;
  • raises no alerts, notifications or CNS insights, and is not counted as down: it drops out of the offline count, the health score and the “worst” rankings. Fleet reports (Wireless, UPS, Signage) list it in grey as Out of service and count it on its own card, and the Help assistant names it apart instead of reporting it as down;
  • is only pinged, lightly, so CreaRack can tell when it is back.

You do not have to remember to bring it back. As soon as the device answers ping again it returns to service by itself and is monitored as before. You can also click Return to Service at any time.

Two things worth knowing: if you take a device out of service while it is still switched on, it will not bounce straight back — it returns only after it has been seen offline and then answers again. And a device that blocks ping (ICMP) cannot announce its own return: bring it back with Return to Service. Devices out of service still count towards your plan.

Reboots

Observatory shows when a device has restarted, not only when it stopped answering. With the Local Agent, CreaRack reads how long each device has been switched on (SNMP sysUpTime) on every traffic reading and notices when that time starts again from zero.

  • Last reboot — a box in the header of the device card with the time of the most recent restart. It only appears once a restart has been seen.
  • Rebooted — in the device’s list of outages, an outage during which the device restarted is tagged Rebooted in the Duration column. A restart is no longer confused with a network loss, and a quick restart that never cost a single ping is now recorded too.

Good to know: it needs Agent 2.43 or later; a device that does not answer sysUpTime shows no reboots; if only the SNMP service of the device restarts (not the device itself) it can be reported as a reboot; and if the device changes its Primary Agent, the first reading after the change is not compared.

Troubleshooting

  • Device missing from the sidebar — it has no IP or no network management in CreaRack. Use Add to monitor it as a manual target.
  • Charts stay empty — checks have just started; data appears after the first refresh cycle. For SNMP, verify credentials first.
  • Monitoring stops when you close the browser — that is Cloud Only behavior by design. Switch to Sentinel mode for 24/7 coverage.
  • [[crearack—monitoring—dashboards]] — Overview dashboard and device detail view
  • [[crearack—monitoring—metricas]] — collected metrics, intervals and retention
  • [[crearack—monitoring—configurar-snmp]] — SNMP polling setup
  • [[crearack—monitoring—alertas]] — alert thresholds and events
  • [[crearack—monitoring—ping-http]] — ping and HTTP checks
  • [[crearack—monitoring—cns-sentinel]] — the AI analysis layer
  • [[crearack—monitoring—itsm]] — incident management
  • [[crearack—monitoring—fleet-manager]] — Local Agent fleet
  • [[crearack—monitoring—deep-discovery]] — vendor-aware deep discovery
  • [[crearack—network—device-page]] — the device card and its polling cadence
  • [[crearack—monitoring—que-es-wireless]] — Wireless Monitor (own module)
  • [[crearack—monitoring—que-es-ups]] — UPS Monitor (own module)